Improving Nanometer Range Accuracy in Measurements
LIF 481 1Dplus, a new type of encoder with x axis and additional y axis.

Today's semiconductors call for measuring devices with high resolution for positioning both in the manufacturing process and in measuring and inspection. Measuring error due to guideway influences and thermal expansion, which at present cannot be compensated by computation, can be ascertained by a new measuring device and therefore significantly reduced.

High Resolution Encoders
The concept of nanotechnology is used for a number of technologies that involve structures and processes in the nanometer range, and it is considered a key technology of the 21st Century. A nanometer is a billionth of a meter (10-9m) and denotes a limit range in which quantum physical effects begin to play an important role. Nanotechnologies such as those seen in optical and semiconductor manufacturing use machines as well as measuring and testing equipment with high positioning accuracy and repeatability. The specified values lie in the range of 100nm to 1nm and even smaller.

The encoders in these machines are subject to very stringent requirements for signal quality and accuracy. These requirements are met by laser interferometers or interferential optical encoders as position measuring devices. Both already offer very high resolutions well below 1 nm. Laser interferometers can be simply aligned with the tool center in order to eliminate Abbe error. One of the most serious disadvantages of these devices, however, is the dependency of the wavelength of laser light on environmental parameters such as temperature and air pressure. These have to be carefully measured along the interferometer's optical path and the error must be continuously compensated for. Any fluctuation, be it ever so small, of temperature, air pressure, the composition of air and similar parameters ultimately results in a change in the wavelength of light and leads over a measuring length of 500mm to position fluctuations in the order of 50nm. The alignment error of the laser, which changes over time, leads to cosine or Abbe error that has to be calibrated continuously.
Arrangement with 2 or 3 scanning heads.


Stable measuring standards normally have a defined thermal behavior and are independent of air pressure fluctuations. In recent years, the LIP, LIF and PP product families from Heidenhain have established themselves as stable measuring standards. The interferential scanning principle behind them exploits the diffraction and interference of light on a fine graduation to produce signals used to measure displacement that are therefore insensitive to air fluctuations. A relative motion of the scanning reticle to the scale causes the diffracted wave fronts to undergo a phase shift: when the grating moves by one period, the wave front of the first order is displaced by one wavelength in the positive direction, and the wavelength of diffraction order -1 is displaced by one wavelength in the negative direction. Since the two waves interfere with each other when exiting the grating, the waves are shifted relative to each other by two wavelengths.
Gantry arrangement with LIF 481 1Dplus, showing an example of the user of 1Dplus scales on a gantry-type milling machine. The x axis is equipped with two heads HX1, HX2 in an example arrangement of the scales. If the tool center point (TCP) is also aligned in Z to the centers of rotation HX1 and HX2, all Abbe offsets of the X axis are equal to zero. The heads HY1 and HY2 detect straightness error (y) of the X guideway axis and, to an extent, the influences of thermal expansion. On the Y axis the heads HX3 and HX4 can be used for compensation of straightness errors in the X axis and Abbe error in the X axis.


This arrangement results in two signal periods from the relative motion of just one grating period. Interferential encoders function with grating periods of, for example, 8µm, 4µm and finer. Their scanning signals are largely free of harmonics and can be highly interpolated. These encoders are therefore especially suited for high resolution and high accuracy and a very high inherent repeatability. Even so, their generous mounting tolerances permit installation in a wide range of applications.

Influence of Guiding Error
All linear bearings have angular guiding error (pitch, yaw and roll) and linear guiding error (straightness, flatness). The error typically lies in the range of 5 to 100µrad or 0.5 to 5µm. The relevant statistical dispersion of this error is only a fraction of these values and is very small for air bearings. Angular guiding error leads to local tilting and, with an Abbe offset other than zero, to a length offset of the encoder and thereby influences the machine accuracy.

Temperature Problems
Temperature fluctuations are true spoilsports for measuring and testing technology when it comes to accuracy and reproducibility. When temperature fluctuates, the accuracy of the system remains limited in spite of expensive designs and materials or additional measures (such as active cooling). Thermally induced geometrical changes of the machine can be mathematically compensated, if only with limitations.

The value of temperature measurement via sensor for linear compensation of thermally induced expansion depends on:

  • The quality of the sensors used.
  • The correct placement (e.g. with inhomogeneous temperature distribution).
  • The aging of the sensors.
  • Calibrated temperature sensors must be continuously monitored and, if required, replaced with good sensors that have the same properties.

Linear motors are also heat sources, especially on fast machines, and can cause thermomechanical deviations. Because of their complex designs, gantry axes require special examination in this context. The influence of guiding error and thermal changes presents great challenges on the road to nanometer-exact positioning within manufacturing processes and in measurement and testing metrology. A new type of measuring device from Heidenhain can contribute to meeting them.

Decades of experience in the field of microstructuring, together with corresponding equipment for scale carrier manufacture and modern structuring and production machines, similar to those found in semiconductor manufacturing, have combined to fulfill the market demand for a quasi two-dimensional measuring device.

Besides the usual longitudinal track (x axis) with the interferential graduation of the familiar LIF (4µm signal period), the LIF 481 1Dplus has an additional y-axis track perpendicular to it. This nevertheless does not require eliminating the reference mark on the longitudinal track. The absolute position on the scale, established by the reference mark, is gated with exactly one measuring step. The glass ceramic ZERODUR® is used in a graduation carrier whose expansion coefficient of 0±0.1 x 10-6 K-1 is exact over a large temperature range and is characterized by high resistance to aging. With the appropriate arrangement of two or three scanning heads the LIF 481 1Dplus linear encoder makes it possible to measure and compensate linear and angular guiding error or the influences of thermal expansion.
Incremental heating X and Y with fast reciprocation (acceleration = 1 g).


Recording the "real-time condition" and compensation of the actual measured values contribute significantly to the improvement of positioning accuracy in the nanometer range. These ambitious expectations of the encoder were confirmed with the impressive results of an experiment.

The inherent repeatability of today's interferential encoders with high resolution is far higher than that of interferometers in air. The effective measuring point of technically perfected encoders is stable and is hardly influenced by tilting. Encoders with 1Dplus scales, which have an additional perpendicular track, contribute to the reduction of Abbe error and the influences of linear guiding errors and thermal expansion. The additional track provides the information required for compensation in the perpendicular direction and for angular correction.

Contact: Heidenhain Corp., 333 E. State Parkway, Schaumburg, IL 60173 847-490-1191 Web: